1
NSF International requires the following water connection:
1. A quick disconnect or additional coiled tubing (at least 2x the depth of the unit) so that the machine
can be moved for cleaning underneath.
2. Thisequipmentistobeinstalledwithadequatebackowprotectiontocomplywithapplicable
federal, state and local codes..
3. Waterpipeconnectionsandxturesdirectlyconnectedtoapotablewatersupplyshallbesized,
installed and maintained in accordance with federal, state, and local codes.
Important Safeguards/Symbols
Thisapplianceisdesignedforcommercialuse.Anyservicingotherthancleaningandmaintenance
shouldbeperformedbyanauthorizedWilburCurtisservicetechnician.
•DoNOTimmersetheunitinwateroranyotherliquid
•Nevercleanwithscouringpowders,bleachorharshchemicals.
Symbols:
WARNINGS–Tohelpavoidpersonalinjury ImportantNotes/Cautions
Sanitation Requirements
Curtis TCCN Units are Factory Pre-Set and Ready to Go… Right From the Box.
Generallytherewillneverbeareasontochangefactorysettings.However,shouldyouneedto
makeslightadjustmentstomeetyourteaneeds,adjustmentinstructionsareprovidedlaterinthis
manual.
System Requirements:
•WaterSource30–90PSI(MinimumFlowRateof1GPM).Ifincomingwatersupplyisgreater
than90PSI,additionalregulationisrequiredtomeettherange.
•Waterpipeconnectionsandxturesdirectlyconnectedtoapotablewatersupplyshallbe
sized,installedandmaintainedinaccordancewithfederal,state,andlocalcodes.
SETUP STEPS
Theunitshouldbelevel(lefttorightandfronttoback),locatedonasolidcountertop.Connect
awaterlinefromthewaterltertotheTCCNteadispenser.NOTE:Sometypeofwaterltration
devicemustbeusedtomaintainatrouble-freeoperation.(Inareaswithextremelyhardwater,we
suggestthatasedimentaryandtaste&odorlterbeinstalled.)Thiswillprolongthelifeofyour
systemandenhanceteaquality.
INSTALLATION
1. Remove dispenser from carton.
2.Runawaterlinetotheinletttingbehindthedispenser.Flushthenewwater-
line to remove foreign particles.
3.Connecta¼”aredexibleorcopperwaterlinetothemalettingontheback
of the dispenser.
4.Locatethewatersupplyvalvebehindtheunittoverifypositionisturnedon.
CAUTION:Werecommendedthatthewatersupplyvalve,behindunit,beturnedoffduring
non-business hours.
ModelsIncluded
•TCC1N
•TCC2N
•TCC3N
NOTE:Watersource
pressure must be a
minimumof30PSI
pressure at all times
toinsurethequalityof
the of the product.
5.CleanouttheteaconcentratesystembeforeusingtheTCCNteadispenser.UseaBIB(Bag-
in-Box)stylecleaningsolutiontosimplifythecleaningprocedure.AcleanerlikeBevClean
beveragelinecleanercomesina3gallonbag-in-boxthatconnectsdirectlytoyourbag-in-box
systemforlinecleaning(http://bevclean.com).
a. PlacetheBIBcleanercontainernexttotheTCCNteadispenser.Pullthespout
from the cleaner box through the marked area. Remove the clear travel cap from
spout.Don’tworryaboutcleanerspillingwhenthecapisremoved.Thespouthas
an internal seal.
b. From the TCCNteadispenser,pulloutthehosewiththeQCD(bagconnector).
ISO 9001:2008 REGISTERED
WILBUR CURTIS CO., INC.
6913 West Acco Street
Montebello, CA 90640-5403
For the latest information go to
www.wilburcurtis.com
Tel: 800-421-6150
Fax: 323-837-2410
Service Manual – TCC1/2/3N
Wilbur Curtis Company, inC.